The safety device consists of the high-voltage section, the static elimination section, and the overcurrent detection section. The overcurrent detection section is built into the high-voltage power supply. |
- |
The overcurrent detection section detects an overcurrent by measuring the return current to the secondary grounding side terminal on the high-voltage transformer and comparing it with the reference input value. |
- |
When it detects an abnormal leakage current on the static eliminating electrode or a high-voltage cable, the safety device shuts off the high-voltage power supply and activates an alarm. |
Model |
Current setting for abnormality detection |
SAT-11 |
Upper limit 2.5 mA constant |
SAT-20 |
3 settings of 2, 3.5, or 5 mA |
SAT-30 |
Digital setting allowed over the range of 0 to 5 mA in increments of 1µA |
|
 |